{"product_id":"bx1500m-lm60-apc-back-ups-pro-1500va-900w-120v-interactive-lcd-10-outlets","title":"APC Back-UPS Pro 1500VA \/ 900W Line-Interactive Battery Backup 120V (Boost \u0026 Trim AVR, 10 NEMA 5-15R Outlets, Multifunction LCD Display, Gigabit Network Surge Protection, Energy Star, Tower Black)","description":"\u003ch4\u003eProduct Overview\u003c\/h4\u003e\n\u003cp\u003eThe \u003cb\u003eBX1500M-LM60\u003c\/b\u003e is an enterprise-tier line-interactive Uninterruptible Power Supply (UPS) manufactured by APC by Schneider Electric under the flagship Back-UPS Pro series. Purpose-built for critical video surveillance recording stations, multi-bay enterprise NVRs\/DVRs, high-capacity PoE network switches, security operations center (SOC) monitoring workstations, network-attached storage (NAS) arrays, and mission-critical telecommunication hardware, this high-capacity unit delivers clean, continuous battery power alongside active voltage conditioning during utility outages, severe voltage sags, brownouts, and destructive electrical transients.\u003c\/p\u003e\n\u003cp\u003eOperating on standard 120V AC (60 Hz) electrical environments with an input regulation window of 88V to 139V AC, the BX1500M-LM60 provides a continuous output capacity of 1500VA \/ 900 Watts. Equipped with Boost and Trim Automatic Voltage Regulation (AVR), it dynamically corrects low and high utility grid fluctuations without cycling the internal battery, preserving runtime for emergencies and extending overall cell life. The rear interface features 10 NEMA 5-15R receptacles, divided into 5 battery backup plus surge-protected outlets for mission-critical hardware and 5 surge-only bypass outlets for peripheral equipment. It integrates a front-panel multifunction LCD status screen, Gigabit Ethernet (RJ45) data line surge protection, USB communication with PowerChute software, and an Energy Star-certified high-efficiency green operating mode.\u003c\/p\u003e\n\u003ch4\u003eKey System Features \u0026amp; Functionality\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eLine-Interactive Topology with Boost \u0026amp; Trim AVR:\u003c\/b\u003e Regulates high and low voltage conditions automatically, keeping equipment running safely on mains power without draining internal batteries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e1500VA \/ 900W High-Capacity Output:\u003c\/b\u003e Powers enterprise NVRs with multiple hard drives, PoE switches, and high-resolution surveillance monitors simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e10 Total Grounded NEMA 5-15R Outlets:\u003c\/b\u003e 5 battery backup + surge protection outlets for primary recording hardware and 5 surge-only bypass outlets for non-critical accessories.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMultifunction Front-Panel LCD Display:\u003c\/b\u003e Provides real-time visual metrics including battery charge level, estimated runtime, load wattage percentage, input\/output voltage, and AVR status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eGigabit Network Data Line Surge Protection:\u003c\/b\u003e Shielded 10\/100\/1000Base-T RJ45 passthrough ports prevent secondary surges from entering recorders via network lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTransformer-Spaced Receptacle Layout:\u003c\/b\u003e Thoughtfully arranged socket pitch accommodates wide DC power adapter blocks without blocking adjacent ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCold-Start Functionality:\u003c\/b\u003e Enables operators to manually boot up connected equipment directly from the UPS battery during a total absence of utility power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eUSB Management \u0026amp; Graceful System Shutdown:\u003c\/b\u003e USB communication port interfaces with APC PowerChute software for automated file saving, event logging, and unattended shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eKey Technical Specifications\u003c\/h5\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eProduct Model \/ SKU\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBX1500M-LM60\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer \/ Brand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAPC by Schneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eProduct Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBack-UPS Pro Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eUPS Topology\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLine-Interactive with Boost \u0026amp; Trim AVR\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutput Power Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VA \/ 900 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eNominal Output Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V AC (±8% on battery mode)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutput Waveform (Battery Mode)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStepped approximation to a sinewave (Simulated Sine Wave)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutput Frequency (Sync to Mains)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz ±1 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eNominal Input Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Operating Voltage Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e88V to 139V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz ±3 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eTransfer Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 ms typical, 10 ms maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eAC Output Receptacles\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 × NEMA 5-15R (5 Outlets Battery Backup + Surge \/ 5 Outlets Surge-Only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eAC Input Connection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAttached 1.83 m (6 ft) power cord with NEMA 5-15P standard grounded plug\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBattery Configuration\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModular 24V DC battery pack (contains 2 × 12V \/ 9Ah VRLA cells, APCRBC124 equivalent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eTypical Recharge Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 16 hours to recover full capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSurge Energy Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 789 Joules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eData Line Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGigabit Ethernet RJ45 10\/100\/1000Base-T surge suppression ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDiagnostic \u0026amp; Control Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultifunction LCD console with Mute, Menu, and Power push buttons\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCommunication Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × USB Type-B port (PowerChute personal edition software support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCircuit Overload Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePush-button resettable thermal circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eAudible Alarms\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlarm on battery, low battery alert, overload tone, system fault alert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEnclosure Material\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeavy-duty, high-impact structural polymer (Tower format)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCertifications \u0026amp; Compliance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnergy Star, RoHS, NOM, UL 1778, FCC Part 15 Class B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +40°C (+32°F to +104°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Relative Humidity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0% to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions (H x W x D)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 250 mm × 100 mm × 382 mm (9.84\" × 3.94\" × 15.04\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eNet Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 11.0 kg (24.25 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"GVS","offers":[{"title":"Default Title","offer_id":50790433882423,"sku":"BX1500M-LM60","price":316.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0894\/7790\/6743\/files\/BX1500M-LM60.png?v=1789141456","url":"https:\/\/shop.gvs-usa.com\/products\/bx1500m-lm60-apc-back-ups-pro-1500va-900w-120v-interactive-lcd-10-outlets","provider":"gvsusa","version":"1.0","type":"link"}